Portable Turbidity Meter with GLP Data Logger - ISO 7027 Compliant, 1/ea.

Portable Turbidity Meter with GLP Data Logger - ISO 7027 Compliant, 1/ea.

Portable White Light Turbidity Meter, EPA 180.1 Compliant, 1/ea.

Portable White Light Turbidity Meter, EPA 180.1 Compliant, 1/ea.

Portable White Light Turbidity Meter with GLP Data Logger, EPA 180.1 Compliant, 1/ea.

Portable White Light Turbidity Meter with GLP Data Logger, EPA 180.1 Compliant, 1/ea.

Portable Turbidity Meter with GLP Data Logger - ISO 7027 Compliant, 1/ea.

Availability: In stock
SKU
AI486
Description
Portable Turbidity Meter Kit
$941.54
Portable Turbidity Meter with GLP Data Logger - ISO 7027 Compliant, 1/ea. is available to buy in increments of 1

Apera TN480 uses an infrared light source and 90° scattering method, which is compliant with the ISO 7027 method. The instrument is designed for water quality professionals, offering long-term reliability in high-accuracy turbidity measurement with an intuitive operating system, simple calibration, and GLP data management.


Feature:

  • The infrared light source is especially ideal for testing solutions with color.
  • TruRead measurement mode automatically takes multiple consecutive readings, and calculate their average, minimum and maximum value, as well as displaying each set of data in a brief test report. TruRead is a much better way to determine the true turbidity of your samples, rather than relying on just one reading. It's especially suitable for sample solutions with rapid settling and continuous measurement changes.
  • The kit comes with AMCO high-molecular polymer turbidity standard solutions (0, 20, 100, 400, 800 NTU), which are EPA approved primary standards that are safe, non-toxic and disposable, and have a guaranteed one-year shelf life. It is NIST traceable to particle size/distribution and optical density, and its inherent stability means it does not settle from suspension. Store the standards at room temperature. They must not be frozen.
  • Zero turbidity error reminder: the instrument has zero-point calibration and zero-point error reminder to ensure high accuracy for low-turbidity solutions.
  • Large TFT color screen with simple operation guide, supporting English, Spanish, and Chinese.
  • 200 sets of data storage with USB data output to PC (Windows-based), real-time clock display, calibration date check, automatic power off, and low battery reminder.
  • Everything comes in a rugged carrying case, including AMCO calibration solutions (0, 20, 100, 400, 800 NTU), 6 pieces of sample vials, USB cable, silicone oil, a microfiber wipe, PC-Link software flash drive, and user manual.



Technical Specifications:

Model Number

AI486

Measurement Method

90° scattering measurement, ISO 7027 compliant

Light Source

Infrared

Measuring Range

0 to 1000 NTU (FNU), automatic range switch

0.01 to 19.99 NTU(FNU)

20.0 to 99.9 NTU(FNU)

100 to 1000 NTU(FNU)

Accuracy

d ±2% of reading+ stray light

Repeatability

d ± 1% of reading or 0.02 NTU(FNU) (the greater of the two)

Resolution

0.01/0.1/1 NTU (FNU)

Stray Light

d0.02 NTU (FNU)

Calibration Standard

AMCO Polymer or Formazin Solution0, 20, 100, 400 and 800NTU (FNU)

Detector

Silicon photovoltaic

Measuring Mode

Normal measurement and TruRead measurement

Data Storage

200 groups

Data Output

USB to PC

Calibration Record

Calibration date and time

Display

TFT color screen

Sample Vial

¦25×60 mm high borosilicate glass with lid

Sample Vial Volume

18 ml

Power supply

3-AAA alkaline batteries

Working Condition

Temperature: 0 to 50°C32°F to 122°F Relative humidity

0 to 90% at 30°C, 0 to 80%at 40°C, 0 to 70% at 50°C, no condensation

Instrument sealing grade

IP67

Certificates

ISO9001:2015 and CE

Limited Warranty

2 years

Dimension and Weight

Meter: (90×203×80) mm/385g

Test Kit: (310×295×110) mm/1.5kg

More Information
Technical Specifications
Model Number

AI486

Measurement Method

90° scattering measurement, ISO 7027 compliant

Light Source

Infrared

Measuring Range

0 to 1000 NTU (FNU), automatic range switch

0.01 to 19.99 NTU(FNU)

20.0 to 99.9 NTU(FNU)

100 to 1000 NTU(FNU)

Accuracy

d ±2% of reading+ stray light

Repeatability

d ± 1% of reading or 0.02 NTU(FNU) (the greater of the two)

Resolution

0.01/0.1/1 NTU (FNU)

Stray Light

d0.02 NTU (FNU)

Calibration Standard

AMCO Polymer or Formazin Solution0, 20, 100, 400 and 800NTU (FNU)

Detector

Silicon photovoltaic

Measuring Mode

Normal measurement and TruRead measurement

Data Storage

200 groups

Data Output

USB to PC

Calibration Record

Calibration date and time

Display

TFT color screen

Sample Vial

¦25×60 mm high borosilicate glass with lid

Sample Vial Volume

18 ml

Power supply

3-AAA alkaline batteries

Working Condition

Temperature: 0 to 50°C32°F to 122°F Relative humidity

0 to 90% at 30°C, 0 to 80%at 40°C, 0 to 70% at 50°C, no condensation

Instrument sealing grade

IP67

Certificates

ISO9001:2015 and CE

Limited Warranty

2 years

Dimension and Weight

Meter: (90×203×80) mm/385g

Test Kit: (310×295×110) mm/1.5kg

We found other products you might like!