Apera TN500 uses a tungsten filament lamp as the light source and 90° scattering method, which is compliant with the U.S EPA 180.1 method for the determination of turbidity in drinking, ground, surface, and saline waters, domestic and industrial wastes. The instrument is designed for water quality professionals, offering long-term reliability in high-accuracy turbidity measurement with an intuitive operation system, simple calibration, and GLP data management.t.

 


Features:




 


 


Technical Specifications:

Model Number

AI483

Measurement Method

90° scattering measurement, U.S EPA180.1 compliant

Light Source

Tungsten filament lamp

Measuring Range

0 to 1000 NTU (FNU), automatic range switch

0.01 to 19.99 NTU(FNU)

20.0 to 99.9 NTU(FNU)

100 to 1000 NTU(FNU)

Accuracy

d ±2% of reading+ stray light

Repeatability

d ± 1% of reading or 0.02 NTU(FNU) (the greater of the two)

Resolution

0.01/0.1/1 NTU (FNU)

Stray Light

d0.02 NTU (FNU)

Calibration Standard

AMCO Polymer or Formazin Solution0, 20, 100, 400 and 800NTU (FNU)

Detector

Silicon photovoltaic

Measuring Mode

Normal measurement and TruRead measurement

Data Storage

200 groups

Data Output

USB to PC

Calibration Record

Calibration date and time

Display

TFT color screen

Sample Vial

¦25×60 mm high borosilicate glass with lid

Sample Vial Volume

18 ml

Power supply

3.7V Rechargeable lithium battery

Working Condition

Temperature: 0 to 50°C32°F to 122°F Relative humidity

0 to 90% at 30°C, 0 to 80%at 40°C, 0 to 70% at 50°C, no condensation

Instrument sealing grade

IP67

Certificates

ISO9001:2015 and CE

Limited Warranty

2 years

Dimension and Weight

Meter: (90×203×80) mm/385g

Test Kit: (310×295×110) mm/1.5kg

More Information
Technical Specifications
Model Number

AI483

Measurement Method

90° scattering measurement, U.S EPA180.1 compliant

Light Source

Tungsten filament lamp

Measuring Range

0 to 1000 NTU (FNU), automatic range switch

0.01 to 19.99 NTU(FNU)

20.0 to 99.9 NTU(FNU)

100 to 1000 NTU(FNU)

Accuracy

d ±2% of reading+ stray light

Repeatability

d ± 1% of reading or 0.02 NTU(FNU) (the greater of the two)

Resolution

0.01/0.1/1 NTU (FNU)

Stray Light

d0.02 NTU (FNU)

Calibration Standard

AMCO Polymer or Formazin Solution0, 20, 100, 400 and 800NTU (FNU)

Detector

Silicon photovoltaic

Measuring Mode

Normal measurement and TruRead measurement

Data Storage

200 groups

Data Output

USB to PC

Calibration Record

Calibration date and time

Display

TFT color screen

Sample Vial

¦25×60 mm high borosilicate glass with lid

Sample Vial Volume

18 ml

Power supply

3.7V Rechargeable lithium battery

Working Condition

Temperature: 0 to 50°C32°F to 122°F Relative humidity

0 to 90% at 30°C, 0 to 80%at 40°C, 0 to 70% at 50°C, no condensation

Instrument sealing grade

IP67

Certificates

ISO9001:2015 and CE

Limited Warranty

2 years

Dimension and Weight

Meter: (90×203×80) mm/385g

Test Kit: (310×295×110) mm/1.5kg