Vaccine Thermometer
- Meets current CDC requirements and additional recommendations for vaccine storage and monitoring
- Use in 21 CFR 11 environments, raw data is locked and may not be cleared/changed on base unit
- Data-logging thermometer with fixed one minute logging interval
Datalogging thermometer that can used in 21 CFR 11 environments.
HI/LO ALARMS AND TIME/DATE STAMPS
Alarm tracking feature stores in memory each alarm event detailing when the alarm state occurred, as well as when the unit returned back to within range. Alarm state indicators include visual LEDs, audio alerts, and flashing LCD segments. Data for up to 10 different alarm events can be retrieved with the most current event viewable on the display.
SMART-ALARM™ SIGNALS OUT-OF-RANGE CONDITIONS
When an out-of-range condition is sensed, the Smart-Alarm™ triggers. Smart-Alarm™ features visual and audible indicators which signal continuously until acknowledged, even if the parameter returns to the non-alarm range.
USB DATA TRANSFERRING
All new feature allows recorded data (CSV file) to be transferred from thermometer to PC (or Mac) using a USB flash drive (not included). No software is needed for computer interface. Each thermometer has a unique ID allowing multiple units to be used in the same location. Raw data on unit cannot be overwritten or modified. Indicator light will appear when 95% of memory is full.
DATA-LOGGING FEATURES
Can be used in environments requiring 21 CFR 11 compliance. Thermometer logs 2 years of observations with a 1 minute logging interval. Device will stop recording when storage is full and will not overwrite recorded data. Data is unable to be deleted from memory once stored.
HIGHLY ACCURATE AND RELIABLE
High-accuracy thermometer has a temperature range of –58 to 158°F (–50 to 70°C) and resolution of 0.01 and maintains an accuracy of ±0.25°C across the entire temperature range. Ideal for monitoring temperatures in refrigerators, freezers, water baths, heating blocks, and incubators.
BOTTLE PROBE FEATURES
Bottle probes are sealed in a miniature bottle (1 x 2-1/2 inches) filled with nontoxic glycol. Solution is GRAS (generally recognized as safe) by the FDA (Food and Drug Administration). Eliminates concerns about incidental contact with food or drinking water. Temperature-buffered bottle sensor eliminates rapid changes when refrigerator door is opened. Ideal for use in monitoring storage conditions for vaccines or other important samples. Meets all current CDC requirements and recommendations for temperature monitoring of vaccine storage as part of the Vaccines for Children program.
TRACEABLE® CERTIFICATE
Multi-point calibration on an individually-numbered Traceable® Certificate which assures accuracy from our ISO/IEC 17025:2005 (1750.01) calibration laboratory accredited by A2LA. It indicates traceability of measurements to the SI units through NIST or other recognized national measurement institutes (NMI) that are signatories to the CIPM Mutual Recognition Agreement. High-impact, chemical-resistant ABS plastic case is 2-3/4 x 4-1/4 x 3/4 inches. Weight is 5 ounces. Supplied: Bottle Probe(1 x 2-1/2 inches), Stand, Velcro®, magnetic strips, wall mount, Traceable® Certificate, and batteries.
Probe Temperature Range | –50.00 to 70.00°C (–58.00 to 158.00°F) |
---|---|
Probe Temperature Resolution | 0.01° |
Probe Temperature Accuracy | ±0.25°C |
# of Probes | 1 |
Included Probe | 1 Bottle designed for refrigerator/freezer applications |
Probe Dimensions | 1 x 2-1/2 inches |
Cable Length | 10' |
Temp MIN/MAX Memory | Y |
Average (Y/N) | N |
Difference (Y/N) | N |
Data Logging | Y |
Exportable Data (Y/N) | Y |
LCD Digit Size | 1/2 in |
Dimensions | 2-3/4"x4-1/4"x3/4" |
Weight | 5 ounces |
A/C Plug (Y/N) | Y(Included) |
Traceable | Y |
CE Marked | Y |
Supplied With | batteries, universal adapter, stand, Velcro®, magnetic strips, wall mount, Traceable® Certificate, batteries |
Current Traceable® Refrigerator/Freezer Digital Thermometers that fulfill the current CDC/VFC requirements. | Basic Monitoring | Digital Dataloggers (DDL) | |||||
4127 | 4730 4731 | 4238 4239 | 6408 | 6430 6431 | 6440 6441 | 6500 6501 | |
CDC Requirements | |||||||
Traceable® Certificate supplied (Traceable to NIST) | |||||||
Calibration Report Included | |||||||
Annual Recalibration by ILAC/MRA accredited laboratory available | |||||||
CDC Reccomendations | |||||||
Glycol encased buffered probe | |||||||
Certificate of Calibration includes methods and procedure documentation | |||||||
Certificate of Calibration includes stated uncertainties | |||||||
Certificate of Calibration includes measurement results | |||||||
Minimum/Maximum Memory | |||||||
Capable of displaying current temperature and minimum/maximum memories | |||||||
Minimum/Maximum Memory reset | |||||||
Detachable probe | |||||||
Adjustable High/Low Alarm | |||||||
Read storage unit temperatures without opening the door | |||||||
±0.5°C (±1°F) Accuracy | ±1°C | ±0.5°C | ±0.3°C | ±0.1°C | ±0.25°C | ±0.25°C | ±0.25°C |
Low battery indicator | |||||||
Temperature Excursion data | |||||||
Data Logger with Continuous Monitoring and Active Display | |||||||
Data Logger with user programmable logging intervals | |||||||
Data Logger capable of storing 4,000 readings that will not overwrite when full |
ISO/IEC 17025 A2LA Accredited • ISO Guide 34 Certified Reference Material Producer
All of Control Company’s Traceable® digital thermometers fulfill the current CDC/VFC requirements.
Each individual state/local health department immunization program may have specific requirements—Consult your immunization program for more information
Data represented above is accurate as of 06/15/2016. Recommendations and requirements are subject to change without prior notice.