Fridge-tag® 2L Fridge-Vaccine Thermometer Data Logger, with Vial and Probe

Fridge-tag® 2L Fridge-Vaccine Thermometer Data Logger, with Vial and Probe

Fridge-tag® 2L Freezer-Vaccine Thermometer Data Logger, with Vial and Probe

Fridge-tag® 2L Freezer-Vaccine Thermometer Data Logger, with Vial and Probe

LogTag TREL30-16 Ultra-Low Freezer Temp Data Logger, with Probe, LTI-HID Interface Cradle, and Wall Mount Bracket

LogTag TREL30-16 Ultra-Low Freezer Temp Data Logger, with Probe, LTI-HID Interface Cradle, and Wall Mount Bracket

Fridge-tag® 2L Fridge-Vaccine Thermometer Data Logger, with Vial and Probe

Availability: In stock
SKU
BERFRIDGETAG2L 1
Description

Vaccine Thermometer

$170.00
Fridge-tag® 2L Fridge-Vaccine Thermometer Data Logger, with Vial and Probe is available to buy in increments of 1

NEW Model with Weekly Graphs, AUDIBLE Alarm & More 

 

Software-Less PDF Generation Temperature / Alarm Data Plus Graphs

 

Fridge-tag® 2L is the ideal Temperature Data Logger for the continuous monitoring of sensitive Vaccines and Pharmaceuticals stored in medical refrigerators & freezers. No software needed to generate temperature & alarm data. As soon as the Fridge-Tag® 2L is connected via USB to a PC or Mac it creates a PDF and an ASCII file. The PDF file provides a daily summary of temperature activity (selectable: 28, 56, 84 or 112 day overview) PLUS 8 weekly graphs of temperature performance. Temperature readings are recorded every 5 minutes and can be found in a table within the TXT file. Thanks to the electronic signature the raw data can be verified as compliant with FDA regulations 21 CFR Part 11. This means that each month you obtain a report and the assurance that your temperature-sensitive goods are stored in accordance with regulations. The data logger’s external thermometer probe is sealed in a Bio-Safe glycol filled bottle to buffer temperature variations. Meets and exceeds the latest VFC CDC requirements published in the 

Exact measurement of temperature and time The Fridge-tag® 2v is a high-precision, electronic temperature monitor. It is 100% calibrated and has a measurement precision of +/- 0.5 °C. Temperature measurement occurs every minute throughout the entire monitoring time. This guarantees faultless and extremely accurate measurement results. Even if an alarm limit has been exceeded and the Fridge-tag®2v alarm is displayed, it accumulates each additional temperature threshold violation. The precision time measurement is generated by a built-in quartz. NIST/ILAC traceable.

Data read-out without software via USB As soon as the Fridge-tag® 2v is connected via USB to a PC or Mac, it creates a PDF or an ASCII file. Thanks to the electronic signature the raw data can be verified to be in compliance with the FDA 21 CFR Part 11 regulations. Any changes are immediately recognized and the document rejected. This means that each month you obtain a report and the assurance that your temperature-sensitive goods are stored and recorded in accordance with regulations.

All models included... 2yr NIST certificate, Vial & Probe.

FEATURES:

  • NIST Traceable with 3 Year Certificate
  • Technician Daily Verification Log
  • Removable Probe
  • True Seal Flat Ribbon Probe Cable
  • Bio-Safe Glycol / Water Probe Medium
  • Current Temperature Display
  • No Software Needed for Computer Interface
  • 30 Day Status on Screen
  • Press for 30-Days of Min/Max History
  • PDF report... 60 days of temperature & alarm data
  • High/Low Alarm
  • 43,200 Temperature Observations Monthly
  • Meets FDA 21 CFR Part 11 requirements
  • Accuracy ±1°F (0.5°C)

 

 

 New Improvments from Fridge-Tag 2V to 2L

Feature ImpactedFeature DescriptionAdvantages
Report DataWeekly GraphsVisual Representation of Records
Report4 graphs – Each with 1 Week of Tempearture Data 
56 Days of Information
Detailed insight to see multiple alarms in 1 day 
More information
Alarm ConditionAUDIBLE AlarmBring Attention to Temperature Excursion
X Goes AwayIf today shows an alarm, press the READ button 4 times to make the X dissapear 
The X comes back even on the same day if the problem persists
Keeps the provider involved with temperatures 
Makes the X important 
Provides relief from constant fear if when the X goes away the problem is addressed
Date in USA FormatUpon start upEasier start up
Date of ActivationA clue for the age of a deviceGive State Health Departments a warning when a device will be out of calibration
Memory ExpandedTemperature readings every 5 minutes for 56 days will be held in the txt fileDetailed analysis of temperatures over time made easy
Cable LengthenedFrom 42” to 62” 
This is an option – the standard length will be 42”
Improve placement of sensor in large vaccine refrigerators
Sensor Port StrengthenedLonger lasting deviceSave money
LCD ScreenIncreased Contrast 
Wider Viewing Angle
Improved visibility of on screen information
Video Support LinkBack label has the URLAnswer Questions / Train
Actual time for checking daily tempsReport shows the actual time a provider checks temperatures 
Shows 2x check per day
Move away from AM / PM – vague time stamps to actual time of check
Battery Level IndicatorShowing Full, Middle and LowImprove user information on the life of the product

 

    

 

Product Manual

More Information
Technical Specifications
External dimensions (L x W x H)128 x 75 x 14.5mm
Size of the LCD display95 x 27mm
Weight96g
Storage condition (inactive)-30°C to +60°C / -22°F to +140 °F
Operating temperature-30°C to +55°C / -22°F to +131 °F
Display visible-10°C to +55°C / +14°F to +131 °F
Alarm temperature range-30°C to +50°C, in 0.1°C increments / -22°F to +122°F
Alarm time1 Minute to 23h 59min
Temperature measurement intervalEvery minute
Accuracy of temperature measurement+/- 0.8 °C (-25 °C to -10 °C) +/- 1.44 °F (-13 °F to +14 °F)
+/- 0.5 °C (-10 °C to +40 °C) +/- 0.9 °F (+14 °F to + 104 °F)
+/- 0.8 °C (+40 °C to +55 °C) +/- 1.44 °F (+104 °F to +131 °F)
Accuracy of time±30 minutes / year
CalibrationEvery device is calibrated / NIST/ILAC traceable
Date/Time programmingDate and time will be set when device is activated 
(see operation manual)
Protection classIP67
Operating lifetimeup to 3 years - expiry date printed on label
ManipulationFridge-tag® 2 cannot be manipulated or reset without destroying it.