Solid Phase Extraction (SPE) 96-Well Plate, Microlute™, 30mg Dosage, SAX, 1ea.

Solid Phase Extraction (SPE) 96-Well Plate, Microlute™, 30mg Dosage, SAX, 1ea.

Solid Phase Extraction (SPE) 96-Well Plate, Microlute™, 30mg Dosage, SCX, 1ea.

Solid Phase Extraction (SPE) 96-Well Plate, Microlute™, 30mg Dosage, SCX, 1ea.

Solid Phase Extraction (SPE) 96-Well Plate, Microlute™, 30mg Dosage, WCX, 1ea.

Solid Phase Extraction (SPE) 96-Well Plate, Microlute™, 30mg Dosage, WCX, 1ea.

Solid Phase Extraction (SPE) 96-Well Plate, Microlute™, 30mg Dosage, SAX, 1ea.

Availability: In stock
SKU
PSAX030P-001
$200.52
Solid Phase Extraction (SPE) 96-Well Plate, Microlute™, 30mg Dosage, SAX, 1ea. is available to buy in increments of 1

MicroluteTM CP takes SPE to a new level of performance by enhancing the reproducibility of analyte extraction and recovery from biological, environmental and chemical samples.


Unlike traditional loose-fi lled SPE methods, MicroluteTM CP uses a hybrid structure, a solid interconnected network of evenly distributed pores combined with the retentive media. This design enhances the fl ow-through of samples to maximise interactions between analytes and the solid phase to deliver a reproducible SPE method that excels in performance, cleanliness and sensitivity.

Enhanced Reproducibility

The goal of any SPE or sample preparation method development is to get the best analyte recovery, while minimizing the concentration of contaminating compounds reaching the final analysis sample. Importantly, the reproducibility of the method, sample-to-sample, day-to-day, week-to-week is critical for greater confidence that your results are more precise. MicroluteTM CP has technology that has a leading design, reducing the variability seen in standard SPE product ranges and guarantees

the highest level of sample reproducibility available.

Variabilities in Traditional Loose-packed Methods

A Solid Start to SPE

The MicroluteTM CP hybrid technology is composed of a solid interconnected network of evenly distributed pores immobilized with chromatographic media within the structure. This results in the formation of a chemically active porous filter or frit, a unique structure that overcomes common inconsistencies and variances often associated with loose-packed methods.

The porous properties of MicroluteTM CP allows for consistent and controlled fl ow of samples throughout the filter, leading to enhanced retention and recovery of precious analytes without any risk of material breakthrough. Meanwhile, the single solid structure eliminates the requirements of extra frits for media support which can further disrupt flow rates and lead to unwanted material breakthrough. The synergy between structure and performance leads to a new method of SPE that promises quality performance with the added benefit of true reproducibility and reliability.

Market Leading Reproducibility

<4% RSD for greater confidence in results Consistent analyte recovery from samples, from well-to-well and batch-to-batch, first time and every time. High-throughput studies benefit from a reproducible, high performing sample preparation workflow.

Technical Specifications:

Model NumberPSAX030P-001
Wells96
Dosage30mg
Function GroupSAX
Qty1
More Information
Technical Specifications
Model NumberPSAX030P-001
Wells96
Dosage30mg
Function GroupSAX
Qty1