rotarus® Volume 50i Peristaltic Pump, White Housing, IP 65 is available to buy in increments of 1

Peristaltic pump for continuous delivery in speed ranges from 0.2 to 100 revolutions per minute

rotarus® volume 50 is a comfortable, precise dispensing pump with control options for velocity, flow rate, dispensing duration and total volume. Variable cycles and graduated pump speeds can be controlled reliably and precisely. Performance class with 50 Watt ensures exact delivery in speed ranges from 0.2 to 100 revolutions per minute. Housings are available with a white powder coating (protection class IP54) and inox stainless steel design (rotarus®volume 50i, protection class IP65).

RFID technology is used in the rotarus® volume to detect the pump head. The model also has automatic blockage detection and hose rupture monitoring. A control panel for the most important functions is integrated directly into the housing. In addition, rotarus® volume is equipped with an external control unit with touchscreen. The pump head connection technology guarantees rapid handling as a standard feature.

Features:

  • Changeable pump heads, single and multichannel design
  • Rapid tool-free changing of pump heads
  • Automatic pump head and hose detection with RFID technology
  • Control panel located directly on pump housing
  • TFT touchscreen with user-friendly menu
  • Calibratable
  • Method memory
  • Operation with 24 V DC
  • USB and RS232 interface for PC link using interface (available as accessory)
  • Pump heads from other manufacturers can be fitted without difficulty using an adapter
  • Comprehensive accessory range

 

Two housing versions with different protection classes are available for rotarus®. The housing with a white powder coating conforms to protection class IP54 and, like the rotarus® smart series housing with protection class IP43, is ideally suitable for use in the laboratory.  The inox stainless steel design with protection class IP65 meets tricter environmental requirements and is the right choice for use in industrial applications in pharmaceutical, medicinal or food production.  

All housing versions have been developed to conform to the fundamental principles of Hirschmann design. Design and functionality also complement each other in rotarus® to produce units which, thanks to their low space requirement, can be easily integrated in an existing laboratory environment or production system, achieving convincing results during use with their sophisticated technology. The smooth housing surfaces can be cleaned without difficulty.

 

Technical Specifications:

Modelsrotarus® volume 50i
Charateristics 
Flow rate range, depending on the pump head used*0.0001 - 1500 ml/min
Changeable pump headsyes
Channels1 - 12 (Depending on the pump head type used)
Range of speed0.2 - 100 1/min
OperationTFT touchscreen
External control moduleyes
Program memory20
Pump direction changeyes
Calibration functionyes
Speed controlLoad-independent
Speed configurationTFT touchscreen
Speed configuration (increments)1/min0.1
Operation modes 
 Pumps according to speed
 Pumps according to flow rate
 Dispensing according to volume
 Dispensing according to time
 Dispensing according to volume in time
 Cycle dispensing
 Cycle time specifi cation
Special functions 
 Tube leakage monitoring (> 30 1/min)
 Blockage detection (> 30 1/min)
 Pump head detection
 Tube detection
 Stackable
 Usable on stand
 Drop-free dispensing
 System assignment
 Soft start
 Tube service life monitoring
 Configurable via menue
Interfaces 
 RS232 interfaces
 USB interface
 Analog input for speed specification
 Analog output for speed
 Digital input Start/Stop; rotation direction
 Selectable digital output
General data 
HousingStainless steel (1.4541) (rotarus® volume 50i)
Continuous modeyes
Motor capacity50 Watt
Motor typeStepper motor
Power consumption60 Watt
Power supply100 - 240 VAC 50 - 60 Hz
Protection classIP65 (rotarus® volume 50i)
StandardsCE
Depth x Width x Height 8.1 x 3.9 x 8.7 in. (205 x 100 x 220 mm)
Weight16.1 lbs. (7.3 kg)


*Flow rate determined with H2O at 0 m suction head and free discharge.



More Information
Technical Specifications
Modelsrotarus® volume 50i
Charateristics 
Flow rate range, depending on the pump head used*0.0001 - 1500 ml/min
Changeable pump headsyes
Channels1 - 12 (Depending on the pump head type used)
Range of speed0.2 - 100 1/min
OperationTFT touchscreen
External control moduleyes
Program memory20
Pump direction changeyes
Calibration functionyes
Speed controlLoad-independent
Speed configurationTFT touchscreen
Speed configuration (increments)1/min0.1
Operation modes 
 Pumps according to speed
 Pumps according to flow rate
 Dispensing according to volume
 Dispensing according to time
 Dispensing according to volume in time
 Cycle dispensing
 Cycle time specifi cation
Special functions 
 Tube leakage monitoring (> 30 1/min)
 Blockage detection (> 30 1/min)
 Pump head detection
 Tube detection
 Stackable
 Usable on stand
 Drop-free dispensing
 System assignment
 Soft start
 Tube service life monitoring
 Configurable via menue
Interfaces 
 RS232 interfaces
 USB interface
 Analog input for speed specification
 Analog output for speed
 Digital input Start/Stop; rotation direction
 Selectable digital output
General data 
HousingStainless steel (1.4541) (rotarus® volume 50i)
Continuous modeyes
Motor capacity50 Watt
Motor typeStepper motor
Power consumption60 Watt
Power supply100 - 240 VAC 50 - 60 Hz
Protection classIP65 (rotarus® volume 50i)
StandardsCE
Depth x Width x Height 8.1 x 3.9 x 8.7 in. (205 x 100 x 220 mm)
Weight16.1 lbs. (7.3 kg)