$ Mystaire® Isola™ PRO 48

Mystaire® Isola™ PRO 48" Ductless Filtered Workstation with EverSafe III Touch Microprocessor Controller, 110V

Mystaire® Isola™ PRO 36

Mystaire® Isola™ PRO 36" Ductless Filtered Workstation with EverSafe III Touch Microprocessor Controller, 110V

Mystaire® Isola™ PRO 72

Mystaire® Isola™ PRO 72" Ductless Filtered Workstation with EverSafe III Touch Microprocessor Controller, 110V

Mystaire® Isola™ PRO 48" Ductless Filtered Workstation with EverSafe III Touch Microprocessor Controller, 110V

Availability: In stock
SKU
MY-ISL48P
Description

Ductless Fume Hood

$7,700.00
Mystaire® Isola™ PRO 48" Ductless Filtered Workstation with EverSafe III Touch Microprocessor Controller, 110V is available to buy in increments of 1

 Isola™ PRO Filtered Workstation Chemical-Resistant Construction with Superior Filtration

Isola PRO polypropylene filtered chemical workstation removes toxic particulate, chemical fumes and vapors protecting both the operator and the environment. Isola PRO polypropylene filtered workstations, standard with a thermally-fused integral spill tray, offer excellent chemical resistance for corrosive applications. Isola PRO polypropylene filtered chemical workstations allow for a wide range of applications. The Isola Series of filtered chemical workstations have been designed to accommodate up to six-inches of filtration.

The design of Isola’s filtration matrix allows for stacking of a HEPA filter, followed by a gas-phased carbon filter, thus allowing the workstation to effectively remove both toxic particulate and chemical fumes and vapors. For high evaporation or multiple chemical applications, a full six-inch stack of gas phase carbon filtration may be incorporated. Isola PRO offers the end user and laboratory many options for fume containment as well as flexibility in laboratory design.

EverSafe™ III TOUCH Control Advanced Microprocessor Safety Controller

The EverSafe™ III TOUCH control advanced microprocessor safety controller is designed to enable simple and precise user control of all hood or workstation functions.  EverSafe™ III has 18 primary control icons that allow the end user to view and or modify the hood or workstation settings.  The primary home screen features display of face velocity to show users they are working with OSHA requirements.  Face velocity is vividly displayed in either linear feet per minute or meters per second.  The lower portion of the EverSafe™ III TOUCH controller screen is designed to give the following information to the end user; current date, time and blower setting.

EverSafe™ III TOUCH control maintains fume hood or workstation face velocity by taking constant measurements at the opening and automatically adjusting airflow to ensure compliance to user preset values.  The end user is allowed to determine desired face velocity through the “Blower Settings” icon.  Mystaire® calibrates and ships each ductless hood and filtered workstation with a preset face velocity of 80 linear feet per minute or 0.4 meters per second. 

Sophisticated electronic controls determine chemical breakthrough based on the type of solvents used within the hood or workstation.  Visible and audible alarms alert the operator if airflow is at an unsafe level or if the installed filters are approaching saturation, allowing sufficient time to replace filters.

EverSafe™ III TOUCH control microprocessor safety controller allows the end user to select the built-in solid state gas detection package sensitivity.  The solid state gas sensor can be set at three distinct levels that correspond to established occupation levels.  A sensitivity level set point should be selected by the end user at is appropriate with the TLV for the current chemical being manipulated.  This provides the end user with an audible and visual alarm that indicates the primary installed filtration has reached saturation and allows the installed safety filtration to protect the end user during experimentation shutdown.

EverSafe™ III TOUCH control displays current installed filtration within the hood or workstation and provides a bar graph consumption monitor to show filter life.  The “FILTERS” icon, when pressed, displays the following filtration type; main, safety and prefilter.   Additionally, the end user can select and change the three types of filters independently of the others.

Energy monitoring is standard with EverSafe™ III TOUCH control and continues to become a focal point of every laboratory.  Cost of operation is a focal point in every business’s operational budget.  EverSafe™ III TOUCH control allows end user display of hood or workstation energy consumption through the “ENERGY USE” icon.  Displayed to the end user is a log of energy consumption, by the ductless hood or workstation, of the life time kilowatt hours and real time power/current/voltage.

Features:

  • 48 inch width (1219 mm)
  • EverSafe™ III TOUCH touch screen controller constantly monitors fume hood performance with audible and visible alarms
  • Vividly displayed status of face velocity in linear feet per minute or meters per second
  • 18-Icon display for simple touch control of hood features and functions
  • LED lighting for true illumination of the entire work area
  • Three-stage filtration to confirm to SEFA 9-2010 DHIII recommendations
  • Single-wall, thermally-fused structural polypropylene construction— superior chemical resistance
  • Solid-state gas detection with three sensitivity set points
  • Conforms to UL, CSA and CE electrical requirements
  • Integral polypropylene spill basin with rolled foil entry
  • Built-in filter and application validation

Vue2

 

 vue

 

Technical Specifications:

Model NumberMY-ISL48P
Work SurfacePolypropylene
ShellPolypropylene
Front SashPolycarbonate
Filtration HousingABS
ControlsEverSafe™ III TOUCH Touchscreen Safety Controller
Face Velocity - Variable60-100 LFM
Lighting LED
BlowersBrushless-Sparkless
Low Airflow AlarmAudible / Visual Alarm
Temperature SensorAudible / Visual Alarm
Humidity Sensor Audible / Visual Alarm
Lab TimerAudible / Visual Alarm
CertificationsUL and CSA Ceritified
Prefilters Required2

Main Filters Required

2
Saftety Filters Required2
External Dimensions (W x D x H)48.8 x 28 x 53
Internal Dimensions (W x D x H)47.5 x 24.7 x 36.8"
Sash Opening Dimensions (W x D x H)45.5 x 9 x 25"
Volumes of Filtered Air1110 CFM
Voltage110 V
Amps4.2 A
Power460 W
Unit Weight225 lbs

 USA

More Information
Technical Specifications
Model NumberMY-ISL48P
Work SurfacePolypropylene
ShellPolypropylene
Front SashPolycarbonate
Filtration HousingABS
ControlsEverSafe™ III TOUCH Touchscreen Safety Controller
Face Velocity - Variable60-100 LFM
Lighting LED
BlowersBrushless-Sparkless
Low Airflow AlarmAudible / Visual Alarm
Temperature SensorAudible / Visual Alarm
Humidity Sensor Audible / Visual Alarm
Lab TimerAudible / Visual Alarm
CertificationsUL and CSA Ceritified
Prefilters Required2

Main Filters Required

2
Saftety Filters Required2
External Dimensions (W x D x H)48.8 x 28 x 53
Internal Dimensions (W x D x H)47.5 x 24.7 x 36.8"
Sash Opening Dimensions (W x D x H)45.5 x 9 x 25"
Volumes of Filtered Air1110 CFM
Voltage110 V
Amps4.2 A
Power460 W
Unit Weight225 lbs