Fridge-tag® 3 GSM Wireless Vaccine Temperature Data Logger

Fridge-tag® 3 GSM Wireless Vaccine Temperature Data Logger

Fridge-tag® 2L Fridge-Vaccine Thermometer Data Logger, with Vial and Probe

Fridge-tag® 2L Fridge-Vaccine Thermometer Data Logger, with Vial and Probe

LogTag TREL30-16 Ultra-Low Freezer Temp Data Logger, VFC Approved Temperature Data Logger, 30 Day Summary, with Probe, & Vial

LogTag TREL30-16 Ultra-Low Freezer Temp Data Logger, VFC Approved Temperature Data Logger, 30 Day Summary, with Probe, & Vial

Fridge-tag® 3 GSM Wireless Vaccine Temperature Data Logger

$264.16
Availability: In stock
Product SKU
BERFRIDGETAG3 1
Fridge-tag® 3 GSM Wireless Vaccine Temperature Data Logger is available to buy in increments of 1

Vaccine Termperature

Receive Real-time Temperature Excursion Alerts via SMS Notifications

Software-Less PDF Generation of Temperature, Alarm Data Plus Graphs

Fridge-tag® 3 is the ideal Temperature Data Logger for the continuous monitoring of sensitive Vaccines and Pharmaceuticals stored in medical refrigerators & freezers.

Real-time SMS text messaging notifications of temperature excursion are transmitted wireless by Cellular GSM (Global System for Mobile communication). The Fridge-tag® 3 is not dependent on Wi-Fi and local networks in order to send SMS Text Messages, and even during power outages can send critical Alerts to your Cell Phone. No software needed to generate temperature & alarm data. As soon as the Fridge-Tag® 3 is connected via USB to a PC or Mac it creates a PDF and CSV file. The PDF file provides a daily summary of temperature activity for the latest 56 days PLUS 8 weekly graphs of temperature performance. Temperature readings are recorded every 10 minutes and can be found in a table within the TXT file. Thanks to the electronic signature the raw data can be verified as compliant with FDA regulations 21 CFR Part 11. This means that each month you obtain a report and the assurance that your temperature-sensitive goods are stored in accordance with regulations. The data logger’s external thermometer probe is sealed in a Bio-Safe glycol filled bottle to buffer temperature variations. Meets and exceeds the latest VFC CDC requirements published in the... Guidelines for Storage and Temperature Monitoring of Refrigerated Vaccines

 

FEATURES:

  • NIST Traceable with 2 year Certificate
  • Removable Probe
  • True Seal Flat Ribbon Probe Cable
  • Bio-Safe Glycol / Water Probe Medium
  • Current Temperature Display
  • No Software Needed for Reporting or Computer Connection
  • 30 Day Status on Screen
  • Press for 30-Days of Min/Max History
  • PDF report... 56 days of temperature & alarm data
  • High/Low Alarm
  • 43,200 Temperature Observations Monthly
  • Meets FDA 21 CFR Part 11 requirements
  • Accuracy ±1°F (0.5°C)
  • Weekly Graphs
  • 8 graphs – Each with 1 Week of Tempearture Data
    56 Days of Information
  • Date in USA Format
  • Date of Activation Give State Health Departments a warning when a device will be out of calibration
  • Battery Level Indicator Showing Full, Middle and Low

 

Technical Specifications:

External Dimensions(L x W x H) 136 x 98 x 21 mm
Size of the LCD Display95 x 27 mm
Weight170 g
Storage Condition(inactive) 0 to +30°C (+32 to + 86°F)
Operating TemperatureMain housing +5°C to +50°C* (+41 to +122°F)
Display visible -10 to +55°C (+14 to +131°F)"
Alarm Temperature Range-40 to +50°C in 0.1°C increments (-40 to +122°F)
Alarm Limits2 individually programmable alarm limits
(1 upper and 1 lower alarm limit)
Warning Limits2 individually programmable alarm limits
(1 upper and 1 lower alarm limit)
Alarm Time1 Minute to 23h 59min (alarm and/or warnings can be disabled)
Temperature measurement intervalEvery minute (Log interval 10 minutes)
Accuracy of temperature measurement+/- 0.8°C from -40 to -30°C (+/-1.44°F from -40 to -22°F)
+/- 0.5°C from -30 to +40°C (+/-0.9°F from -22 to +104°F)
+/- 0.8°C from +40 to +55°C (+/-1.44°F from +104 to +131°F)
Measurement accuracy of the timeDaily time updates (depending on network operator) - if not supported +/- 30 min / year
CalibrationEvery device is calibrated / NIST / ILAC traceable
Memory Space30 day as a display and 56 days overview in a PDF report
Date / Time programmingDate and time will be set automatically when device is activated (via GSM network)
BatteryLithium Polymer Li-ion battery
Complies with IATA DGR Packaging Instruction UN3481 PI 967 section ll
and is therefore not considered as dangerous good.
Protection ClassIP50 (IP64 without external sensor)
2D Code on LabelGS1 and data matrix
Operating LifetimeMin. 3 years useful life / at least 72 hours power back up
ActivationPress SET and READ button simultaneously for more than 3 seconds
StoppingNo stop function
ConfigurationPre-set by Berlinger & Co AG or for self configuration via server
Data CommunicationOptional: To be pushed on a regular interval to a predefined server
Alarm IndicationBuzzer, SMS or server
ManipulationFridge-tag® 3 GSM cannot be manipulated or reset without destroying it.
Format of the original documentASCII (it can also be imported by many ERP systems) / PDF
Free software for verifying
PDF and ASCII Files
"JAVA™ / The software verifies the digital signature of the ASCII and PDF files.
FDA regulation 21 CFR Part 11 compliant. Software is compliant with GAMP 5 requirements.
StandardsASTM 2500, 21 CFR Part 11, 21 CFR Part 820, ICH Q8/Q9, ANSI/IEEE 829/830/1008,
EN 12830, 2002/95 EC Directive (RoHS), EN/IEC 60529 IP protected classes, 
IATA Regulations, EN 301511, EN 301489-1/7, EN 60950-1 + A2:2013, EN 62133, FCC part 15B

 Note: 2 year data plan required for SMS Alerts

Bio Safe  USB  

 

Product Manual


Fridge-tag 3 Installation & Data Plan Instructions 

More Information
Technical Specifications
External Dimensions(L x W x H) 136 x 98 x 21 mm
Size of the LCD Display95 x 27 mm
Weight170 g
Storage Condition(inactive) 0 to +30°C (+32 to + 86°F)
Operating TemperatureMain housing +5°C to +50°C* (+41 to +122°F)
Display visible -10 to +55°C (+14 to +131°F)"
Alarm Temperature Range-40 to +50°C in 0.1°C increments (-40 to +122°F)
Alarm Limits2 individually programmable alarm limits
(1 upper and 1 lower alarm limit)
Warning Limits2 individually programmable alarm limits
(1 upper and 1 lower alarm limit)
Alarm Time1 Minute to 23h 59min (alarm and/or warnings can be disabled)
Temperature measurement intervalEvery minute (Log interval 10 minutes)
Accuracy of temperature measurement+/- 0.8°C from -40 to -30°C (+/-1.44°F from -40 to -22°F)
+/- 0.5°C from -30 to +40°C (+/-0.9°F from -22 to +104°F)
+/- 0.8°C from +40 to +55°C (+/-1.44°F from +104 to +131°F)
Measurement accuracy of the timeDaily time updates (depending on network operator) - if not supported +/- 30 min / year
CalibrationEvery device is calibrated / NIST / ILAC traceable
Memory Space30 day as a display and 56 days overview in a PDF report
Date / Time programmingDate and time will be set automatically when device is activated (via GSM network)
BatteryLithium Polymer Li-ion battery
Complies with IATA DGR Packaging Instruction UN3481 PI 967 section ll
and is therefore not considered as dangerous good.
Protection ClassIP50 (IP64 without external sensor)
2D Code on LabelGS1 and data matrix
Operating LifetimeMin. 3 years useful life / at least 72 hours power back up
ActivationPress SET and READ button simultaneously for more than 3 seconds
StoppingNo stop function
ConfigurationPre-set by Berlinger & Co AG or for self configuration via server
Data CommunicationOptional: To be pushed on a regular interval to a predefined server
Alarm IndicationBuzzer, SMS or server
ManipulationFridge-tag® 3 GSM cannot be manipulated or reset without destroying it.
Format of the original documentASCII (it can also be imported by many ERP systems) / PDF
Free software for verifying
PDF and ASCII Files
"JAVA™ / The software verifies the digital signature of the ASCII and PDF files.
FDA regulation 21 CFR Part 11 compliant. Software is compliant with GAMP 5 requirements.
StandardsASTM 2500, 21 CFR Part 11, 21 CFR Part 820, ICH Q8/Q9, ANSI/IEEE 829/830/1008,
EN 12830, 2002/95 EC Directive (RoHS), EN/IEC 60529 IP protected classes, 
IATA Regulations, EN 301511, EN 301489-1/7, EN 60950-1 + A2:2013, EN 62133, FCC part 15B