$ Mystaire® Aura™ Elite 42

Mystaire® Aura™ Elite 42" Ductless Fume Hood, 110V

Mystaire® Aura™ Elite 30

Mystaire® Aura™ Elite 30" Ductless Fume Hood, 110V

Mystaire® Aura™ Elite 54

Mystaire® Aura™ Elite 54" Ductless Fume Hood, 110V

Mystaire® Aura™ Elite 42" Ductless Fume Hood, 110V

Availability: In stock
SKU
MY-AU42
Description

Ductless Fume Hood

$9,200.00
Mystaire® Aura™ Elite 42" Ductless Fume Hood, 110V is available to buy in increments of 1

Aura® Elite Ductless Fume Hood

Aura Elite is the next advanced solution for ductless fume hood technology. For over 15 years Mystaire Aura ductless fume hoods have provided customers with market leading safety features and reliable service. The new Aura Elite includes the latest in microprocessor-based controls, including constant monitoring of fume hood face velocity, gas phase filtration saturation, temperature and humidity monitoring, along with instantaneous filter to chemical application validation.

Each of these features is vividly displayed and controlled by the EverSafe III touch screen controller, which offers a user's finger-tip control.

EverSafe™ III TOUCH Control Advanced Microprocessor Safety Controller

The EverSafe™ III TOUCH control advanced microprocessor safety controller is designed to enable simple and precise user control of all hood or workstation functions.  EverSafe™ III has 18 primary control icons that allow the end user to view and or modify the hood or workstation settings.  The primary home screen features display of face velocity to show users they are working with OSHA requirements.  Face velocity is vividly displayed in either linear feet per minute or meters per second.  The lower portion of the EverSafe™ III TOUCH controller screen is designed to give the following information to the end user; current date, time and blower setting.

EverSafe™ III TOUCH control maintains fume hood or workstation face velocity by taking constant measurements at the opening and automatically adjusting airflow to ensure compliance to user preset values.  The end user is allowed to determine desired face velocity through the “Blower Settings” icon.  Mystaire® calibrates and ships each ductless hood and filtered workstation with a preset face velocity of 80 linear feet per minute or 0.4 meters per second. 

Sophisticated electronic controls determine chemical breakthrough based on the type of solvents used within the hood or workstation.  Visible and audible alarms alert the operator if airflow is at an unsafe level or if the installed filters are approaching saturation, allowing sufficient time to replace filters.

EverSafe™ III TOUCH control microprocessor safety controller allows the end user to select the built-in solid state gas detection package sensitivity.  The solid state gas sensor can be set at three distinct levels that correspond to established occupation levels.  A sensitivity level set point should be selected by the end user at is appropriate with the TLV for the current chemical being manipulated.  This provides the end user with an audible and visual alarm that indicates the primary installed filtration has reached saturation and allows the installed safety filtration to protect the end user during experimentation shutdown.

EverSafe™ III TOUCH control displays current installed filtration within the hood or workstation and provides a bar graph consumption monitor to show filter life.  The “FILTERS” icon, when pressed, displays the following filtration type; main, safety and prefilter.   Additionally, the end user can select and change the three types of filters independently of the others.

Energy monitoring is standard with EverSafe™ III TOUCH control and continues to become a focal point of every laboratory.  Cost of operation is a focal point in every business’s operational budget.  EverSafe™ III TOUCH control allows end user display of hood or workstation energy consumption through the “ENERGY USE” icon.  Displayed to the end user is a log of energy consumption, by the ductless hood or workstation, of the life time kilowatt hours and real time power/current/voltage.

Features:

  • 42 inch width (1067 mm)
  • EverSafe™ III TOUCH touch screen controller constantly monitors fume hood performance with audible and visible alarms
  • Vividly displayed status of face velocity in linear feet per minute or meters per second
  • 18-Icon display for simple touch control of hood features and functions
  • Variable airflow control with automatic airflow sensor calibration — no service technician required
  • Temperature and humidity sensor to monitor filter performance
  • Solid-state gas detection with three sensitivity set points
  • Conforms to UL, CSA and CE electrical requirements
  • Fiberglass spill tray
  • Built-in filter and application validation
  • LCD readout of airflow in linear feet per minute or meters per second
  • Meets applicable OSHA and ANSI standards
  • ASHRAE 110-1995 certified
  • SEFA 9 DH III Compliant

Vue2

 

Aura

 

Technical Specifications:

Model NumberMY-AU42
Base / Work SurfaceRemovable Fiberglass Tray
Side WindowsClear Polycarbonate
ShellPolypropylene Epoxy Powder-Coated Aluminum
Front SashPolycarbonate
Filtration HousingPolypropylene
ControlsEverSafe™ III TOUCH Touchscreen Safety Controller
Face Velocity - Variable60-100 LFM
Lighting Vapor-Proof Flurescent
BlowersBrushless-Sparkless
Low Airflow AlarmAudible / Visual Alarm
Temperature SensorAudible / Visual Alarm
Humidity Sensor Audible / Visual Alarm
Lab TimerAudible / Visual Alarm
CertificationsUL, CSA, and ASHRAE Certified
Pre-Filters Required2
Main Filters Required2
Safety Filters Required2
External Dimensions (W x D x H)42 x 28 x 50
Internal Dimensions (W x D x H)41.2 x 25.5 x 30.0"
Sash Opening Dimensions (W x D x H)41.5 x 8 x 22.8"
Volume of Fitlered Air500 CFM
Voltage110 V
Amps4.4 A
Power480 W
Unit Weight285 lbs

 USA

More Information
Technical Specifications
Model NumberMY-AU42
Base / Work SurfaceRemovable Fiberglass Tray
Side WindowsClear Polycarbonate
ShellPolypropylene Epoxy Powder-Coated Aluminum
Front SashPolycarbonate
Filtration HousingPolypropylene
ControlsEverSafe™ III TOUCH Touchscreen Safety Controller
Face Velocity - Variable60-100 LFM
Lighting Vapor-Proof Flurescent
BlowersBrushless-Sparkless
Low Airflow AlarmAudible / Visual Alarm
Temperature SensorAudible / Visual Alarm
Humidity Sensor Audible / Visual Alarm
Lab TimerAudible / Visual Alarm
CertificationsUL, CSA, and ASHRAE Certified
Pre-Filters Required2
Main Filters Required2
Safety Filters Required2
External Dimensions (W x D x H)42 x 28 x 50
Internal Dimensions (W x D x H)41.2 x 25.5 x 30.0"
Sash Opening Dimensions (W x D x H)41.5 x 8 x 22.8"
Volume of Fitlered Air500 CFM
Voltage110 V
Amps4.4 A
Power480 W
Unit Weight285 lbs